— 23 —
KV-21FA210
ADJUSTMENT ITEMS (6 OF 8)
DEVICE "DEFD"
Item# OSD DETAIL
Range
(DEC)
Initial Data
1 VSTP V OUTPUT STOP 00-01 0
2 HFFR AFC1 FORCE FREERUN 00-01 0
3 HFUP H FREERUN FREQUENCY UP(700Hz) 00-01 0
4 VPHA V PHASE(V POSITION ADJUST) 00-15 0
5 JSWW Jump Pulse Width 00-01 0
6 EWG EWV AD OUTPUT LEVEL(6db) 00-01 0
7 EWCL EW/VRAMP DA CLOCK SELECT 00-03 2/YUV:2
8 EWDI EW/VRAMP DA DITHER 00-01 0
9 XF0A VCXO FREERUN ADJUST 00-15 0
10 BGST BGP(for PLL) TIMING 00-63 17
11 SKWI Skew correcter reference phase 00-01 0/YUV:0
12 XPHA VCXO PHASE ADJUST 00-15 10
13 SKEW Skew corrector phase control 00-07 0/YUV:3
14 HRMP AFC2 TIME CONSTANT 00-03 0
15 RPLU REF PLL TIME CONSTANT 00-07 3
16 RPLB REF PLL TIME CONSTANT 00-01 1
17 XF0B VCXO Fo ADJUST 00-03 0
18 RPLS REF VCO FB LOOP SELECT 00-01 0
19 SSM SyncSepaMasking CONTROL 00-01 0
20 VSAG V-SAG prevent ON 00-01 0
21 AFC2 AFC2 GAIN CONTROL 00-03 0
22 VRFL V RAMP FILTER SWITCHING OFF 00-01 0
23 SSLP LPF pre SYNC SEPA ON/OFF 00-01 0
24 IMTS I.M. TEST 00-01 0
25 XPLU ACP TIME CONSTANT 00-01 1
26 8FSC 8fscCLK Skew OFF 00-01 1/YUV:1
27 4FS2 4fscCLK Skew OFF 00-01 1/YUV:1
28 EWVR DSDAC V RESET Enable 00-01 0
29 VLOF IIC V Latch OFF(for TEST) 00-01 0
30 1WIN FORCE 1Window 00-01 1
31 BGPC ANGLE Return current up 00-01 0
32 MHDL ANGLE Return current up timing 00-01 1
33 BFRE force V FREERUN 00-01 0
34 ANGG ANGLE Retun current up 00-01 1
35 ANGT ANGLE Retun current up timing 00-01 0
36 DOSD Digital OSD ON 00-01 0
37 ANGS AFC2 ANGLE/BOW INHIBIT 00-01 0
38 HRPP FRAMP RRAMP H OUT CONTROL RANGE 00-15 8
39 VF50 FORCE V FREERUN 50Hz 00-01 0
40 CLKS TBC clock system select 00-03 0
41 VBHK V BLK HALF KILL 00-01 0
42 DSYC CVBS INPUT CONTROL 00-01 0
43 VPW V Pulse Wide 00-01 1
44 QSW MODULATOR FEEDBACK GAIN CONTROL 00-01 0
45 ADTY CLOCK DUTY CONTROL at IIC QSWITCH=ON 00-01 0
46 DTH DITHER THRESHOLD LEVEL CONTROL at IIC AUTOD=ON 00-03 1
47 HBSW HBLK REFERENCE AFC1/AFC2 00-01 0
48 DSCS ǻȈDAC CLOCK ON/OFF CONTROL 00-01 0