CASSETTE CASSETTE
TAPE TAPE
PB • REC •
Signal Pin No. I/O EJECTED
LOADING UNLOADING
THREAD- UNTHREAD- STOP FF REW PB
PAUSE
SLOW × 2 CUE REVIEW REC
PAUSE
ING ING
CAM
MA-350
O Hi-Z H L H L *7 *7 *7 *7 *7 *7 *7 *7 *7 *7 *7
IC161*£
MODE 1
MA-350
IH L L *1 *1 HHHHHHHH L HH
IC161*¢
MODE 2
MA-350
IH L L *1 *1 HHHLLLLL L LL
IC161*∞
MODE 3
MA-350
IL L L *1 *1 HLLLLLLL H LL
IC161*§
MODE 4
MA-350
IL H H *1 *1 LHHLLLLL L LL
IC161*¶
REC PRF
MA-350
IH *2 *2 *2 *2 *2 *2 *2 *2 *2 *2 *2 *2 *2 *2 *2
IC161%∞
T REEL
MA-350
I H/L H/L H/L H/L H/L H/L *3 *3 *3 H/L *3 *3 *3 *3 *3 H/L
IC161*•
S REEL
MA-350
I H/L H/L H/L *3 *3 H/L *3 *3 *3 H/L *3 *3 *3 *3 *3 H/L
IC161*ª
END-LED
MA-350 O
*4 *4 *4 *4 *4 *4 *4 *4 *4 *4 *4 *4 *4 *4 *4 *4
IC161&¢ (O.D)
CAP RVS
MA-350
I L H L H/LHLHHHHH L HH
IC161(£
T SENS
MA-350
I *4 *4 *4 *6 *6 *6 *6 *6 *6 *6 *6 *6 *6 *6 *6 *6
IC161!™
S SENS
MA-350
I *4 *4 *4 *6 *6 *6 *6 *6 *6 *6 *6 *6 *6 *6 *6 *6
IC161!¡
5-3. SYSTEM CONTROL – MECHANISM BLOCK INTERFACE (MA-350 BOARD IC161)
∗1. Uncertainty.
∗2. “L” when erasing protection tab is bent, “H” when not bent.
∗3. Pulse of period in proportion to reel rotating speed.
∗4. Approx. 2 msec period “H” pulse.
∗5. Pulse at tape running.
∗6. Normally “L”. 2 msec period “H” pulse when tape top or tape end is detected.
∗7. When transition to UNLOADING direction: L.
When transition to LOADING direction: H.
When CAM motor is stopped: Hi-Z.