[GC Test Mode]
Enter the GC Test Mode
Procedure 1:
1. Press the I/1 button to turn the power on.
2. While pressing the both [STEREO/MONO] *
1
and [2CH/
MULTI C] buttons, press the [CLOCK/TIMER] *
1
button.
3. LEDs and fluorescent indicator tube are all turned on of all
units.
Procedure 2:
1. Press the I/1 button to turn the power on.
2. While pressing the both [PLAY MODE] *
2
and x *
2
buttons,
press the Z (DISC 1) *
2
button.
3. LEDs and fluorescent indicator tube are all turned on of all
units.
Version Display Mode
Procedure:
1. Enter the GC test mode.
2. Each time the [TUNER MEMORY] *
1
or [DISC 1] *
2
button is
pressed, microcomputer or mechanism deck version is dis-
played of each unit.
3. Press the [TUNING +] *
1
or [DISC 3] *
2
button to detail is
displayed the version.
Key Check Mode
Procedure:
1. Enter the GC test mode.
2. Press the [TUNING --] *
1
or [DISC 2] *
2
button to set the key
check mode.
3. In the key check mode, the fluorescent indicator tube displays
“K 0 J 0 V 0”. Each time a button is pressed, “K” value in-
creases. However, once a button is pressed, it is no longer taken
into account.
“J” value increases like 1, 2, 3 ... if turn the
[FILE SELECT]
knob clockwise, or it decreases like 0, 9, 8 ... if turn the JOG
dial counterclockwise.
“V” value increases like 1, 2, 3 ... if turn the [VOLUME] knob
clockwise, or it decreases like 0, 9, 8 ... if turn the JOG dial
counterclockwise.
Releasing the GC Test Mode
To release from this mode, press three buttons in the same manner
as entering this mode or disconnect the power cord.
SECTION 4
TEST MODE
Note: Use following buttons in the test mode.
no mark : Button of amplifier unit (TA-S3)
*1 : Button of tuner unit (ST-S3)
*2 : Button of CD unit (CDP-S3)
[MC Test Mode]
Enter the MC Test Mode
1. Press the I/1 button to turn the power on.
2. While pressing the both [STEREO/MONO] *
1
and [2CH/
MULTI C] buttons, press the [MUSIC MODE A] button.
3. “GROOVE” indication blinks on the fluorescent indicator tube
in the midst of MC test mode.
4. This mode has two modes (mode 1/mode 2).
5. To change the modes, press three buttons in the same manner
as entering this mode (step 2). Each time the step 2 operation
is repeated, it changes modes alternately.
6. To distinguish the mode, turn the [VOLUME] knob clockwise
or counterclockwise. Then display is shown as follows.
Mode 1: only “MIN” or “MAX”
Mode 2: “MIN”, “1 to 30” or “MAX”
Releasing the MC Test Mode
To release from this mode, press the I/1 button or disconnect the
power cord.
w
w
w
.
x
i
a
o
y
u
1
6
3
.
c
o
m
Q
Q
3
7
6
3
1
5
1
5
0
9
9
2
8
9
4
2
9
8
T
E
L
1
3
9
4
2
2
9
6
5
1
3
9
9
2
8
9
4
2
9
8
0
5
1
5
1
3
6
7
3
Q
Q
TEL 13942296513 QQ 376315150 892498299
TEL 13942296513 QQ 376315150 892498299
http://www.xiaoyu163.com
http://www.xiaoyu163.com