EasyManuals Logo

SOR 200 series User Manual

Default Icon
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #49 background imageLoading...
Page #49 background image
Registered Quality System to ISO 9001:2008
49/60
Form 912
sorinc.com
913-888-2630
Description
Model Series
100 200
108/
208
300 400
741-743
802
740
804
700 730 750
AF
1
FE
CL
Air Filter & Gauge
Finned Extention
ATEX Approved for S3 Hsg
CN
7
CP7
CR7
Conduit Reducer M20 x 1.5
Conduit Reducer 1/2” NPT
Conduit Reducer 3/4” NPT
CS
2
CV
CY
CSA Certification
Canadian Registration Number (CRN)
Certificate of Conformance
(power plant piping, ANSI 31.1)
CZ
3
DN
EC
8
Certificate of Conformance
(petrochemical piping, ANSI 31.3)
Special Drain Connection
Extra Chamber Connection
C/F
C/F
C/F
C/F
C/F
ET
5
FE
GG
Temperature Extension
Finned Extention
Sealed Conduit
ID
9
KK
MC
4
Interface Detection
Housing Breather Drain
Manual Check
MR
MT
NC
Mill Test Report
Mag Particle Examination
NACE Construction
PP
PT
PY
RR
Fiber Tag
Dye Penetration Examination
Powder coat epoxy coating.
No coating on
stainless steel parts or plated screws.
(500 hrs. salt spray)
SS Tag wired to housing
RT
SC
10
SD
11
Radiograph Examination
Special Calibration
Special Dimensions
C/F
C/F
C/F
C/F
C/F
C/F
C/F
C/F
C/F
C/F
C/F
C/F
C/F C/F C/F
SL
12
TC
4
Special Cable Length
Tru-Check
TF
TT
Tandem Floats
Oversized Nameplate for customer tagging
C/F
C/F
UT
VV
WC
WV
2
Ultrasonic Examination
Fungicidal Varnish
Water Column Unit
UL Listed
C/F


YY Epoxy Coating (enclosure only)
Accessories
741A -A1C-B-A1-N4-CRTT
Notes C/F = Consult the Factory
1. Pneumatic switching mechanisms only (P1)
2. Consult switch and housing sections for agency availability.
3. Process media must be known prior to manufacture. Different
processes (service categories) require different quality
inspection procedures. Consult the factory for details.
4. Appropriate for Model Series 701 through 704 and 730
through 733. See page 55 for details. Not available with NACE.
5.
See high-temperature selection for application.
SOR accessories are provided for customizing the level switches in this
catalog according to the requirements of the application. Place accessory designator(s) from the table below at the
end of the model number. Check the compatibility chart below for correct use of each accessory.
6. Not available with agency-listed housings.
7. Not available with T6 and S3 (ATEX) housings.
8. Need connection size, type, and location on chamber.
9.
The upper and lower specific gravity required to determine functionality.
10.
Operating specific gravity, Set Point (referenced from upper
process connection) and if Set Point is rising or falling are required.
11. Specific details of chamber dimensional changes.
12. Length of cable required (10 ft. is standard).
Accessory Compatibility Chart
Mechanical
Level Switches

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SOR 200 series and is the answer not in the manual?

SOR 200 series Specifications

General IconGeneral
BrandSOR
Model200 series
CategorySwitch
LanguageEnglish

Related product manuals