Installation and Operation Sorensen DCS Series 1kW and 1.2kW Supplies
2-6 M362500-01 Rev H
2.4.3 J3 Program, Sense and Monitor Connector Description
D-subminiature 25-pin female; mating connector: 25-pin Male ITT Cannon DB25P or equivalent
AC/DC Shutdown Input (12-250 Vac or 12-130 Vdc)
Return for Shutdown Input Signals
OVP Programming Input (0-5V, 0-10V, or 0-1mA)
Jumpered to pin 16 for local mode operation
Remote Programming Indicator (high=remote programming, low=local control)
Operating Mode Indicator (high=voltage mode, low=current mode)
Output Current Monitor (calibrated) 0-5V=0-100%
Front Panel Voltage Control (remote programming)
Input for 0-1mA remote programming signal
Jumpered to pin 9 for local operation and remote current source programming
Remote Voltage Programming Input (0-5V or 0-10V)
Jumpered to pin 8 for local operation and remote current source programming
Remote Current Programming Input (0-100mV, 0-5V, or 0-10V)
Jumpered to pin 11 for local operation and remote current source programming
Front Panel Current Control (remote programming)
Input for 0-1mA external programming signal
Jumpered to pin 10 for local operation and remote current source programming
Return Sense (return for remote programming inputs)
+12 Vdc Output (1k ohm source impedance)
1mA Current Source for Local OVP Control or Remote Resistive OVP Programming
OVP Status (high=OVP circuit activated)
Thermal Shutdown Indicator (high=shutdown)
Output Voltage Monitor (uncalibrated) 0-5V=0-100%
Front Panel Voltage Control (local mode); jumpered to pin 21 for local operation
1mA Current Source for Local Operation or Remote Resistive Programming of
Output Voltage; jumpered to pin 20 for local operation
1mA Current Source for Local Operation or Remote Resistive Programming of
Output Current Limit; jumpered to pin 23 for local operation
Front Panel Current Control (local mode); jumpered to pin 22 for local operation
Return (for local sense connections only)
Positive Output (for local sense connections only)
Note: Pins 25 and 13 not connected on 150, 300, and 600V models.