1. Viscosity adjustment is set
incorrectly.
2. Inadequate mix in hopper.
3. Improper mixing of product.
4. Air tube isn’t installed correctly.
5. Product is being drawn too
quickly.



1. Starved cylinder
2. Inadequate mix in hopper.
3. Improper mixing of product.
4. Air tube isn’t installed correctly.
5. Viscosity adjustment is set
incorrectly.
6. Air pump is not primed

Malfunconing temperature probe

Replace temperature probe.


1. Ensure hopper is at least half full.
2. Follow manufacturer instrucons for
mixing product; ensure correct mix raos.
3. Lower viscosity seng as required.
4. Ensure air tube isn’t clogged, allow
machine 2 to 5 seconds between servings.
5. (G) Clean air tube, ensure proper
orientaon.
6. (A) Check to make sure hand screws ght
on pump shell body and that shell gasket is
installed.
7. Prime air pump
8. Turn on DEFROST mode. (Page 15)

Malfunconing power board.

Replace power board.


1. Install the dispensing door.
2. Check and reinstall jumper on display
board.

1. Dispensing door is o.
2. Jumper on display board is
disconnected or loose.


1. Ensure hopper is at least half full.
2. Follow manufacturer instrucons for
mixing product; ensure correct mix raos.
3. Lower viscosity seng as required.
4. 5. Ensure air tube isn’t clogged, allow
machine 2 to 5 seconds between servings.
5. (G) Clean air tube, ensure proper
orientaon.
6. (A) Check to make sure hand screws ght
on pump shell body and that shell gasket is
installed.
7. Prime air pump
8. Turn on DEFROST mode. (Page 15)