FOCUS 35 TOTAL STATION USER GUIDE
4 – Setup
61
External EDM Calibration When entering this menu the cursor stays always at
the P key. Press P when number is correct - the
system jumps back to the Service Menu.
To enter another value press N or O and the first
digit of the Scale is active (inverse) and with N and
O the numbers 0-9 can be selected. Press P when
number is correct - cursor jumps to the next digit.
After you have selected the last digit for the Scale
press P . The cursor jumps to the settings for Offset
with the same procedure.
When last digit of Offset is confirmed, the system
jumps back with the cursor to the inverse P symbol.
Press P key a further time - the system jumps to
Service Menu.
Service Menu - Drive Mode Settings for Drive Mode:
Drive Mode settings have an effect while using
LockNGo Tracker technology for robotic surveying or
while changing face.
Press N and O to scroll to Drive Mode and then
press P.
Drive Mode Press N and O to select Normal or Fast and then
press P.
Normal:
This mode is the default mode. Mode is suitable
for all instrument mounts.
Fast:
Mode can be a choice for instrument mount on
tripods.
Screen Actions and Comments
Ext. EDM Calibration
Scale 1.000000
Offset[mm] +00.0
Ext. EDM Calibration
Ext. EDM Frequency
Service Menu
Drive mode
Radio config
Normal
Drive mode
Exit
Fast