Spectra 1728/EX & 1738/EX - 11 - Programming Guide
Bold
= Default Setting
* Not to be used with UL installations.
SECTION [130]: Arming/Disarming Options
Option
OFF ON
[1]
One-Touch Regular Arming* N Disabled N Enabled
[2]
One-To uch Stay Armi ng * N Disabled N Enabled
[3]
One-To uch Force Armi ng* N Disabled N Enabled
[4]
One-Touch Bypass Programming* N Disabled N Enabled
[5]
Restrict Arming on Battery Failure N Disabled N Enabled
[6]
Restrict Arming on Tamper Failure N Disabled N Enabled
[7]
Bell Squawk on Arm/Disarm with Keypad N Disabled N Enabled
[8]
Beep on Exit Delay N Disabled N Enabled
SECTION [131]: Arming/Disarming Options
Option
OFF ON
[1]
Report Disarming N Always N Only after alarm
[2]
Regular Arming Switches to Force Arming* N Disabled N Enabled
[3]
Bell Squawk on Arm/Disarm with Remote Control
(must be enabled for UL installations)
N Disabled N Enabled
[4]
No Exit Delay When Arming with a Remote Control N Disabled N Enabled
[5]
No Exit Delay Beeps and No Bell Squawk When
Stay Armi ng
N Disabled N Enabled
[6]
Restrict Arming On Wireless Transmitter
Supervision Loss
N Disabled N Enabled
[7]
Generate Supervision Loss if Detected on
Bypassed Wireless Zone
N Yes N No
[8]
Future Use N N/A N N/A
SECTION [132]: Zone Options
Option
OFF ON
[1]&[2]
N see table
N see table
N see table
N see table
[3]
Generate Tamper if detected on Bypassed Zone N Yes N No
[4]
EOL (end-of-line) Resistors N No EOL N Use EOL Resistors
[5]
ATZ Zone Doubling (1728 and 1738 only) N Disabled N Enabled
[6]
Report Zone Restore N On Bell Cut-off N On Zone Closure
[7]&[8]
N see table
N see table
N see table
N see table
Tam per Recognition Options
[1] [2]
OFF OFF Disabled (default)
OFF ON When disarmed: GENERATES TROUBLE ONLY
When armed: Follows Zone Alarm Types
ON OFF When disarmed: GENERATES SILENT ALARM
When armed: Follows Zone Alarm Types
ON ON When disarmed: GENERATES AUDIBL E ALARM
When armed: Follows Zone Alarm Types
Wireless Transmitter Supervision Options
[7] [8]
OFF OFF Disabled (default)
OFF ON When disarmed: GENERATES TROUBLE ONLY
When armed: Follows Zone Alarm Types
ON OFF When disarmed: GENERATES SILENT ALARM
When armed: Follows Zone Alarm Types
ON ON When disarmed: GENERATES AUDIBL E ALARM
When armed: Follows Zone Alarm Types