Spectra 1728/EX & 1738/EX - 12 - Programming Guide
Bold = Default Setting
* Not to be used with UL installations.
SECTION [133]: Partition 1 Options
Option
OFF ON
[1]
Auto-Arm on Time N Disabled N Enabled
[2]
Auto-Arm on No Movement N Disabled N Enabled
[3]
Auto Arming = Regular or Stay* N Regular Arming N Stay Arming
[4]
Switch to Stay Arming if no entry delay is opened N Disabled N Enabled
[5]
Stay Arming with Delay Partition 1 (Delay = [070]) N Disabled N Enabled
[6]
Future Use N N/A N N/A
[7]
Future Use N N/A N N/A
[8]
Future Use N N/A N N/A
SECTION [134]: Partition 2 Options
Option
OFF ON
[1]
Auto-Arm on Time N Disabled N Enabled
[2]
Auto-Arm on No Movement N Disabled N Enabled
[3]
Auto Arming = Regular or Stay* N Regular Arming N Stay Arming
[4]
Switch to Stay Arming if no entry delay is opened N Disabled N Enabled
[5]
Stay Arming with Delay Partition 2 (Delay = [070]) N Disabled N Enabled
[6]
Future Use N N/A N N/A
[7]
Future Use N N/A N N/A
[8]
Future Use N N/A N N/A
SECTION [135]: Dialer Options
Option
OFF ON
[1]&[2]
N see table
N see table
N see table
N see table
[3]
Reporting (Dialer) N Disabled N Enabled
[4]
Dialing Method N Pulse Dialing N Tone (DTMF) Dialing
[5]
Pulse Ratio N 1:2 N 1:1.5
[6]
If armed, activate bell output on Com. Failure N Disabled N Enabled
[7]
Future Use N N/A N N/A
[8]
Future Use N N/A N N/A
Teleph one Lin e Mo nitoring ( TLM) Options
[1] [2]
OFF OFF TLM Disabled (default)
OFF ON TLM generates a trouble if armed
ON OFF TLM generates an audible alarm if armed
ON ON Silent alarms become audible