Spellman SL Series - Figure 5.5 Polarity Reversal Procedures, 1 Kv to 8 Kv (600 W to 1200 W); Figure 5.6 Polarity Reversal Procedures 10 Kv to 130 Kv (600 W to 1200 W)

Default Icon
68 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SL SERIES MANUAL 26 118006-001 REV Y
R E V . A
A S S Y 4 0 4 2 3 0 -
J B 1
J2
R 2 6
J1
J4
CR4
E1
J3
J B 2
T B 1
O U TP UT C URRE NT :
SP ECI AL FE AT URE S:
SPELLM AN
H I G H V O L T A G E E L E C T R O N I C S C O R P
P L A I N V I E W , N Y 1 1 8 0 3 M A D E I N U S A
PA RT NO . :
M O DE L :
PO L ARI T Y:
O U TP UT V O LT AG E :
DANGER
HI G H VO LTAG E
O U TP UT P O W ER :
1
115V
T1
E 3 6
E2
E 3 7
J B 2
JB2
J B 3
1
4
220V
115V
E 3 9
E 3 8
J B 9
J B 8
J B 7
J B 5
G2E 2 DE1G1 G1E1 E 2 DG2
E 3 0E 2 8
E 2 7E 2 0
E 1 3
E9 E 1 1
E 1 4
C1
E2
C 2 E 1
Q3
C1
E2
C 2 E 1
J3 J2
J4
J P 1 2
J P 1 3
J1
L1
Q2
L2
REMOVE COVER BY UNSCREWING AND REMOVING 12 SCREWS
THAT MOUNT COVER TO CHASSIS AND FRONT PANEL.
REMOVE 4 SETS OF HARDWARE THAT HOLD THE LEXAN COVER
TO THE HIGH VOLTAGE BOARD, AND REMOVE COVER.
TURN UNIT OFF, UNPLUG LINE CORD FROM AC OUTLET AND
WAIT FOR 5 MINUTES BEFORE PROCEEDING TO CHANGE THE
HIGH VOLTAGE MULTIPLIER.
1
2
REINSTALL LEXAN COVER AND RELATED HARDWARE.
REINSTALL POWER SUPPLY'S COVER AND ALL HARDWARE BEFORE
4
3
FOR POSITIVE POLARITY:
BLACK WIRE ON J4 AND WHITE WIRE ON J5.
FOR NEGATIVE POLARITY:
WHITE WIRE ON J4 AND BLACK WIRE ON J5.
SWAP BLACK AND WHITE WIRES BETWEEN J4 AND J5 AS FOLLOWS:
TURNING UNIT ON.
2
3
2
LI NE LO AD
600 to 1200 Watt
1kV to 8kV chassis
R E V . AA S S Y 4 0 4 1 2 9 - 0 0 1
1
5
1
4
S / S R E V . A
E4
J4
E2
JB 1
J B 2
J B 3
C1
E2
C2 E 1
G2E 2 DE1G1 G1E1 E 2 DG2
C1
E2
C2 E 1
1
1
AS S Y 4 0 3 9 3 5 -
RE V . A
S L 6 0 0 W - 1 2 0 0 W
CO N T R O L / P O W E R BD
115V
220V
115V
J B 1
J3 J2
J4
T1
J P 1 2
J P 1 3
J1
E 3 9
E 3 6
E2
E 3 7
J B 5
J B 2
E 3 8
Q3
J B 7
J B 6
E3
T B1
E 3 0E2 8
E 2 7E 2 0
E 1 3
E9 E1 1
E 1 4
L1
Q2
JB2
L2
J B 3
1
4
HIGH VOLTAGE
MULTIPLIER
8
UNIT ON.
INSTALL COVER AND ALL HARDWARE BACK BEFORE TURNING
5
7
6
4
3
2
1
HIGH VOLTAGE MULTIPLIER.
W AIT FOR 5 MINUTES BEFORE PROCEEDING TO CHANGE THE
TURN UNIT OFF, UNPLUG LINE CORD FROM AC OUTLET AND
REVERSE.
INSTALL NEW MULTIPLIER BY FOLLOWING STEPS 6 THRU 2 IN
CAREFULLY TILT UP AND SLIDE OUT MULTIPLIER.
ENCLOSURE AND THE BOARD TO THE CHASSIS
REMOVE 2 SCREW S THAT HOLD THE POLYETHYLENE
THAT MOUNT COVER TO CHASSIS AND FRONT PANEL.
REMOVE COVER BY UNSCREW ING AND REMOVING 12 SCREW S
FROM FASTON TAB ON BOARD.
UNPLUG CABLE FROM JB1 AND REMOVE CABLE SHIELD
UNPLUG CONNECTOR FROM JB2.
UNPLUG HIGH VOLTAGE LEADS FROM ASSEMBLY.
7
3
5
6
4
9
LI NE LO AD
600 to 1200 Watts
10kV to 120kV chassis
Figure 5.5 -- Polarity Reversal Procedures
600W to 1200W, 1kV to 8kV Chassis
Figure 5.6 -- Polarity Reversal Procedure
600W to1200W, 10kV to 120kV Chassis

Table of Contents