101501-565 Rev C Page 42 of 58
6.6.4 Request kV Setpoint
Description:
The host requests that the firmware report the kV setpoint.
Direction:
Host to supply
Syntax:
<STX><14><,><CSUM><ETX>
Response:
If an error is detected, the Power Supply responds with:
<STX>14,!,<ERROR>,<CSUM><ETX>
Please reference the Error Code section for a list of valid error codes..
If the message is accepted, the Power Supply responds with:
<STX>14,<ARG>,<CSUM><ETX>
Where:
<ARG> = 0 - 4095 in ASCII format
Example Response:
KV setpoint is set to full scale.
<STX>14,4095,<CSUM><ETX>