Data di emissione: Dicembre, 2018 Revisione: 2 Pag. : 41/68
14. TROUBLESHOOTING GUIDE
NOTE: the following procedures must be performed by a qualified service technician.
Problem Possible cause Solution
The machine does not cool,
or cools only partially and
the compressor is running
The space around the machine is
inadequate for ventilation
The refrigeration system is working in
DEFROST mode
The condenser fins are clogged with
airborne particles
Fan motor is not running
Refrigerant is leaking
Allow at least 20cm between the
machine and anything next to it;
keep it away from heat sources
Return to FREEZE mode
Clean the condenser fins
Check the fan motor’s electrical
connections and, if disconnected,
reconnect. If still not operating,
replace the motor
Locate the leak, eliminate it and
recharge the system
The machine does not cool,
or cools only partially and
the compressor is not
running
Electrical components of the compressor
are not functioning
Some electrical connections are not
complete
The compressor is malfunctioning
Replace the malfunctioning
components
Check the contacts and and
correct those incomplete
Replace the compressor
The machine is noisy The fan motor blades are hitting internal
components
Check and correct
The main power switch is
“ON” but the unit s not
running
The main cover is not correctly
assembled
Some electrical connections are not
complete
The main power switch is broken
The control board is faulty
The compressor DC drive is faulty
The gear motor is malfunctioning
Assemble the main cover
correctly
Check the contacts and and
correct those incomplete
Replace the switch
Replace the control board
Replace the DC drive
Replace the gear motor
The bowl is leaking
One of the bowl seal is not in place
Replace or reposition the seal
The dispensing valve is
leaking
The dispensing valve has been
incompletely or incorrectly replaced in its
position
The free movement of the valve is
impeded
Dispensing valve o-rings are damaged
Reassemble and replace
Clean and lubricate the valve
and the valve cylinder with the
lubricant provided with the
machine
Replace the o-rings
Product is flowing into drain
tray through drainage pipe
The bell shaped seal between the front of
the cylinder and the auger hub has not
been reinstalled properly
The bell shaped shaft seal or the spindle
bushing seal is damaged or worn
Find the seal and put it back in
place
Replace the damaged/worn seal
and check the condition of the
drive shaft
The auger is not turning The main cover is not correctly
assembled
Some electrical connections are not
complete
The control board is faulty
The compressor DC drive is faulty
The gear motor is malfunctioning
Assemble the main cover
correctly
Check the contacts and correct
those incomplete
Replace the control board
Replace the DC drive
Replace the gear motor
The auger is creating noise
as it rotates
The bell shaped shaft seal has been
replaced without lubrication or is
damaged
The auger has been incompletely or
incorrectly reassembled
Replace or clean and lubricate
with the lubricant provided with
the machine
Check and correct
The first and last LED of the
consistency scale are
blinking at the same time
and the machine does not
cool
The product level inside the bowl is too
low
Refill the bowl with product until
the level probe is covered