Data di emissione: Dicembre, 2018 Revisione: 2 Pag. : 38/68
11. SPECIAL MAINTENTANCE
FOR SERVICEMAN ONLY
!Caution!
Before proceeding with any maintenance
operation, it is compulsory to switch off the
machine and unplug it from the mains.
Condenser cleaning
In order to guarantee good cooling system
performance, the condenser must be well
cleaned every month.
How to reach it:
- Switch off the power supply and disconnect
the power cable;
-GT1 machine: remove the rear panel by
unscrewing the two bolts fastening it (fig.28);
-GT2 machine: remove the left side panel by
unscrewing the two bolts fastening it (fig.29);
- Using a dust exhauster, remove the dust that
has collected between the condenser fins
(fig.30).
!CAUTION!
In order to avoid any kind of damage to the
refrigerating system during any special
maintenance operation, never use a
screwdriver or sharp object to clean
between fins.
!CAUTION!
In order to reduce risks related to the
refrigerant flammability, every special
maintenance operation has to be
performed ONLY by skilled service men.
Fig. 28
Fig. 29
Fig. 30