SAFETY POWER SUPPLY CORD:
This Portable Air Conditioner is provided with a Leakage Current Detection
and Interruption circuit (LCDI) built into the plug of the power supply cord.
This device provides protection to reduce the risk of fire due to arcing faults in
the power-supply cord. Each time before using the Portable Air Conditioner,
follow the "Plug Testing Instructions" given below to ensure that the LCDI
circuit is functioning properly.
PLUG TESTING INSTRUCTIONS:
1. PRESS TEST BUTTON. UNIT SHOULD TRIP.
2. PRESS RESET BUTTON FOR USE.
Note: Please do not use this item if above test fails.
The conductors inside this power supply cord are surrounded by shields,
which monitor the leakage current. These shields are not grounded.
Periodically examine the cord for any damage. If the shield gets exposed,
immediately unplug the power supply cord and do not use the Portable Air
Conditioner. Do not repair a damaged cord. Replace the damaged cord with a
new replacement power supply cord or obtain a new replacement power
supply cord by calling Sunpentown Int'l Inc. at 1-800-330-0388.
in the event the LCDI Plug of the power supply cord trips by itself, first
examine the cord for any damage. If there is no damage to the cord then
press the RESET Button. If the LCDI P!ug trips again, then immediately
unplug the power supply cord. Replace the damaged cord with a new
replacement power supply cord or obtain a new replacement power supply
cord by calling Sunpentown Int'l Inc. at 1-800-330-0388.
Do not use The TEST and RESET Buttons as an ON / OFF switch. They are
only meant to periodically check the LCDI plug".