EasyManuals Logo

SPX FLOW APV DELTA SD4 Series User Manual

SPX FLOW APV DELTA SD4 Series
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #18 background imageLoading...
Page #18 background image
13
APV_SD4_ATEX_UK-0_122018.indd
UK
Double seal valve
DELTA SD4-ATEX
Instruction Manual: UK - rev. 0
APV
9. TechnicalData
9.1. Generaldata
- Product-wetted parts: 316 L, 1.4404 (DIN EN
10088)
- Other parts: 1.4301 (DIN EN 10088)
- Seals: standard design: EPDM
- option: HNBR, VMQ, FPM
- Max. line pressure: 10 bar
- Operating pressure: depending on actuator
- see pos. 9.6
- Max. operating temperature: 135°C EPDM, HNBR
*FPM, *VMQ
- Short-termload: 140°CEPDM,
HNBR *FPM, *VMQ
*(no steam)
- Ambient temperature: 0 - 40 °C
- CIP connection for leakage valves: G1/8
- Air connection (for hose): 6 x 1 mm
- Max. pneumatic air pressure: 8 bar
- Min. pneumatic air pressure: 6 bar
Use dry and clean air, only.
9.2. Compressedairquality
- Compressed air quality: quality class according to ISO 8573-1
- Content of solid particles: quality class 3,
max. number of particles per m³
10000of0,5μm<d≤1,0μm
500of1,0μm<d≤5,0μm
- Content of water: quality class 4,
max. dew point temperature - 20 °C
For installations at lower temperatures
or at higher altitudes, additional
measures must be considered to reduce
the pressure dew point accordingly.
- Content of oil: quality class 1,
max. 0,01 mg/m³
The oil applied must be compatible with Polyurethane elastomer
materials.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SPX FLOW APV DELTA SD4 Series and is the answer not in the manual?