INSTRUCTION MANUAL
ORIGINAL INSTRUCTIONS
READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT.
TopGear GP
INTERNAL GEAR PUMPS
A.0500.451 – IM-TG GP/07.02 EN (03/2016)

Table of Contents

Questions and Answers

  • F
    fosterjessicaAug 23, 2025
    Why SPX FLOW TG GP58-80 has no flow?
    • W
      wwhiteAug 23, 2025
      If your SPX FLOW Water Pump has no flow, it might not be priming due to several reasons. The suction lift could be too high. Reduce the difference between the pump and suction tank level, or increase the suction pipe diameter, or reduce the length and simplify the suction pipe. Check for air leaks in the suction line and repair them. If the viscosity is very low, increase the pump speed and reduce axial clearance. Ensure the suction strainer or filter is clear. Verify the pump casing is correctly installed. Finally, check the motor's rotation; for 3-phase drivers, switch two connections, or change the suction and discharge opening, but be careful to check the location of the safety relief valve.
  • R
    Rick HendersonNov 5, 2025
    What to do if SPX FLOW TG GP58-80 stalls or has irregular flow?
    • R
      Robert PatelNov 6, 2025
      If your SPX FLOW Water Pump is stalling or experiencing irregular flow, several issues could be the cause. Check if the liquid level in the suction tank is too low and correct the liquid supply or provide a level switch. The pump output might be too high; if so, reduce the pump speed or install a smaller pump, or install a bypass line with a check valve. Air could be getting sucked in; repair any leaks in the suction line, check or replace the shaft seal, check or provide a quench on the shaft seal, or connect plug Bb to the pump discharge to increase pressure in the sealing box. Cavitation could also be the issue; reduce the difference between the pump and suction tank level, increase the suction pipe diameter, or reduce the length and simplify the suction pipe. Finally, the liquid may be...

Summary

1.0 Introduction

1.3 Safety

Details critical safety instructions, warnings, and precautions for operating and servicing the pump.

3.0 General technical information

3.2 Operating principle

Describes how the internal gear mechanism functions to transport liquid.

3.4 General performance

Highlights important considerations for pump application and liquid properties.

3.5 Main characteristics

Presents key performance data, dimensions, and specifications for different pump sizes.

3.6 Pressure

Defines differential, working, and hydrostatic test pressures for the pump line.

3.7 Sound level

Provides sound level data for pumps without drive and discusses influences on total unit sound.

3.8 Material options

Details available material choices for pump components and their temperature limits.

3.17 Shaft sealing

Details shaft sealing options, including packed glands and packing ring materials.

3.18 Safety relief valve

Describes the safety relief valve, its types, materials, pressure classes, and adjustments.

3.19 Installation

3.19.6 Suction and discharge pipes

Covers forces, moments, piping design, isolation valves, strainers, and self-priming.

3.19.8 Guidelines for assembly

Offers guidance for assembling the pump unit with drives, including motor and coupling.

3.20 Instructions for start-up

3.20.4 Checklist - Initial start-up

A comprehensive checklist to ensure all steps are completed before the first start-up.

3.20.5 Start-up

Details the procedure for starting the pump and verifying its operation.

3.20.7 Abnormal operation

Provides guidance on handling abnormal operations and troubleshooting issues.

3.21 Trouble shooting

3.22 Maintenance instructions

3.22.3 Specific components

Provides maintenance details for specific parts like nuts, bolts, gaskets, bearings, and shaft seals.

4.0 Instructions for assembly and disassembly

4.5 Anti-friction bearings

Details the disassembly and assembly procedures for anti-friction bearings.

4.6 Relief valve

Provides instructions for the disassembly and assembly of the safety relief valve.

6.0 Dimensional drawings

6.4 Safety relief valves

Presents dimensional drawings for single, double, and heated safety relief valves.

SPX FLOW TG GP58-80 Specifications

General IconGeneral
BrandSPX FLOW
ModelTG GP58-80
CategoryWater Pump
LanguageEnglish