Waukesha Cherry-Burrell Introduction
10/2010 95-03009 Page 13
Performance
Characteristics
Authorization
3A/USDA (Sanitary Models)/EHEDG
Standard Construction
• Casing: 316L Stainless Steel
• Port Connections: S-Line
• Backplate: 316L Stainless Steel
• Impeller W/Integral Shaft: 316L Stainless Steel
• Impeller Retainer: 316L Stainless Steel
• Shaft Seal: Single Mechanical, external balanced (Type 1)
• Rotary Seal Material: Carbon
• Stationary Seal: Siliconized Graphite
• Elastomers: FDA approved FKM
• Finish: All product contact surfaces ar
e pr
ovided with a sanitary
polish (150 Grit). Industrial pumps are unpolished.
The motor adapter bracket is painted with a cast iron
paint; a two-part
epoxy, TNEMEC 104, Sky-Blue #104-BB-42 on the motor bracket
and motor (if ordered).
• Mounting: Close coupled for JM shafted motors
Construction Options
Ports
Bevel Seat
Female I-Line
Male I-Line
Q-Line
Butt-weld
Female or Male N.P.T
150 Lb. Flange, DIN or SMS
Seal Type
• Water Cascade (Type 1C)
• Double Mechanical w/flush (Type 4 Shaft Seal)
• WFI - Special Type 4 shaft seal for wa
ter for injection applications
• Aseptic Shaft Seal - barrier flush design
• Commercially available seals (Contact your WCB representative for
details)
Rotary Seal Material
Purebide
Silicone Carbide
Tungsten Carbide
Stationary Seal
Silicone Carbide
Tungsten Carbide

Table of Contents