10.4 Erasing measurements
The RD8200 locator allows you to delete all
measurements. Erasing the survey measurements will
wipe the RD8200 memory and is usually recommended
when you begin a new survey and you have saved your
previous measurements.
WARNING! Erasing measurements cannot be undone!
Proceed with caution!
To erase all stored measurements:
1 Press the key to enter the menu
2 Press the or keys to select SMLOG menu
3 Press the key to enter the SMLOG menu
4 Press the or keys to select the DATA menu
5 Press the key to enter the DATA menu
6 Press the or keys to select the DEL
7 Press the key to enter the DEL menu
8 Press the or keys to select YES
9 Press the key to make the selection and return to
the main menu
10.5 Retrieving all survey
measurements via Bluetooth
Survey measurements stored in the locator’s memory
can be transferred wirelessly to a compatible Android
device running RD Map for post survey analysis.
To Obtain RD Map
1. On your Android device open Google’s Play Store
2. Search for RD Map by Radiodetection Ltd
3. Install the app
Refer to the RD Map operation manual for more info on
how to retrieve stored survey measurements.
10.6 Retrieving all survey
measurements via USB
Stored data can also be transferred using the USB
connection to the RD Manager Online software package
to be analyzed by the software’s built-in Survey
measurements capabilities.
Refer to the RD Manager Online operation manual for
more info on how to retrieve stored survey
measurements.
RD Manager Online’s Survey measurements
functionality can be used for post survey analysis,
interface to Google Earth® and easy export to GIS /
mapping systems.
NOTE: RD Manager Online is compatible with PCs
running Windows 10 64 bit.
To obtain RD Manager Online:
Visit https://www.radiodetection.com/rdmanager_online
10.7 Troubleshooting
Successful wireless communication depends on a
number of factors including: battery life, electromagnetic
interference, device memory and physical obstructions.
Ensure that the RD8200 locator and any other
compatible wireless device is sufficiently charged for
wireless communication.
Excessive electromagnetic interference can limit the
range of wireless communication and / or corrupt data.
The RD8200 locator must be within 10m (30ft) from the
compatible paired device to maintain a wireless
connection.
Resetting connections
If you experience problems with the RD8200 wireless
Bluetooth technology features, Radiodetection
recommends resetting the connection and then pairing
your device again.
To reset the wireless Bluetooth connections:
1 Press the key to enter the menu
2 Scroll to the SMLOG menu using the or keys
3 Press the key to enter the SMLOG menu
4 Scroll up or down to the RESET menu
5 Press the key to enter the RESET menu
6 Select YES using the or keys
7 Press the key to enter the iLOC menu
8 Re-pair your devices as described in section 10.2
Bluetooth error codes
If an error occurs when during any Bluetooth
communication between the locator and the compatible
device, the locator’s LCD will display a code to help you
resolve the problem. The codes are as follows:
BT Code
Description
BT001
Bluetooth not configured for this unit
BT002
Internal Bluetooth error
BT004
Locator not paired with PCPDA
BT005
Paired but connection attempt failed. Power
cycling may be required
BT009
Corrupt response received from paired device
BT010
Transmission to paired device failure