9.
Turn
on
each
burner
control
and
light
in
turn.
Check
for
a
clear
blue
flame
without
excessive
yellow
tipping.
If
burners
show
any
abnormal
combustion
check
they
are
correctly
located.
Sometimes
burners
may
not
ignite
immediately
and
may
seem
to
"blow"
slightly
when
they
do
ignite.
This
is
usually
due
to
air
in
the
gas
line,
which
should
clear
itself.
10.
If,
after
following
the
instructions,
satisfactory
performance
cannot
be
obtained,
contact
the
local
gas
authority
for
advice
and
assistance.
11.
For
minor
adjustments
see
Servicing
and
Minor
Adjustments.
12.
A
two
(2)
yearly
inspection
of
the
appliance
by
an
authorised
service
agent
will
ensure
many
years
of
trouble
free
service
(Note:
This
is
not
provided
under
warranty).
7.2
Injector
Sizes
for
Gas
Cooktops
MODEL
BURNER
NATURAL
GAS
UILPG
INJECTOR
0
mm
MJ/hr
INJECTOR
0
mm
MJ/hr
0029
RAPID
1.60
12.0
0.92
11.0
SEMI-RAPID
1.18
6.0
0.65
5.4
CG29WOK
WOK
1.80
14.5
0.95
12.0
CG60WOKFFE
RAPID
1.60
12.0
0.92
11.0
SEMI-RAPID
1.18
6.0
0.65
5.4
______
______
_____
WOK
1.80
14.5
0.95
12.0
CG90WOKFFE
RAPID
1.60
12.0
0.92
11.0
SEMI-RAPID
1.18
6.0
0.65
5.4
AUXILIARY
0.90
4.0
0.5
3.2
WOK
1.80
14.5
0.95
12.0
CG90WOKFFEF
SEMI-RAPID
1.18
6.0
0.65
5.4
AUXILIARY
0.90
4.0
0.5
3.2
WOK
1.80
14.5
0.95
12.0
______
______
_____
FISH
1.4
9.5
0.85
1
10.0
26