L I F T F E AT U RE S
L I F T F E AT U RE SL I F T F E AT U RE S
L I F T F E AT U RE S
DIGITAL DISPLAY OPERATION
DIGITAL DISPLAY OPERATIONDIGITAL DISPLAY OPERATION
DIGITAL DISPLAY OPERATION
The digital display on the console will visually indicate lift operation to the user, floor num-
bers and arrows. In the unlikely event of the lift obtaining a fault, the display may be used
to present fault codes to aid fault finding for the engineer. If these are observed please
make a note of them to communicate to the engineer upon arrival.
DUAL CONTROL (OPTION)
DUAL CONTROL (OPTION)DUAL CONTROL (OPTION)
DUAL CONTROL (OPTION)
Where required, a second set of platform controls can be specified and fitted opposite the
main operating console. The second set of controls typically a duplicate of the car operat-
ing buttons including the alarm button. The controls are on a ‘first come, first serve’ basis
(i.e. neither set of controls has priority). The operation and function of the lift is otherwise
unchanged.
FIRE ALARM SHUT DOWN
FIRE ALARM SHUT DOWNFIRE ALARM SHUT DOWN
FIRE ALARM SHUT DOWN
Some buildings have a lift interface for the fire alarm system. When activated, the lift will
automatically travel to the ground floor should a fire alarm occur, all calls will be disabled
and the car door open button will still operate allowing users to exit the lift.
FOLD DOWN SEAT (OPTION)
FOLD DOWN SEAT (OPTION)FOLD DOWN SEAT (OPTION)
FOLD DOWN SEAT (OPTION)
If optioned for your lift, the fold down seat provides seating for one person for the duration
of the lift travel. When not it use it will fold away to occupy less space.
OVERLOAD CONDITION
OVERLOAD CONDITIONOVERLOAD CONDITION
OVERLOAD CONDITION
The lift will have a maximum load rating identified on the console. Should this load be ex-
ceeded, the lift will stop operation, display a flashing ‘OL’ on the digital display and an-
nounce “lift overload”. Should this occur, the additional load should be removed from the
lift to return to normal service.
ROOF FAN (OPTION)
ROOF FAN (OPTION)ROOF FAN (OPTION)
ROOF FAN (OPTION)
Where required, a fan can be can be fitted into the roof, drawing in fresh air to increase
circulation in hot climates.