MANUFACTURER menu
10
[DPO Oā]
this parameter for the inlet valve sets the delay time for
the pressure test at the start of the irrigation cycle in
order to fill the tube (maximum time settable 999
seconds)
[WI O:OO] Waiting start Irrigation. The waiting time, in hours and minutes, can be set by using the second function of the H key.
Maximum waiting time settable is 99 hours 59 minutes. The waiting time can be modified and activated before each Start
Irrigation. If set to 0, the parameter does not appear; if a value other than 0 is set, the programmed value is offered as
default.
Pressing _>_ takes you to a sub-menu with the following options:
[ENMA WTI]
[ENRU WTI]
[ENMU WTI]
=>ENables Modification by the Assistance
=>ENables Read-only by the User
=>ENables Modification by the User
These options enable or disable the choice of Waiting Time before Irrigation, by theassistance or
the user.
[ SECTORS] If it is enabled, it permits the management of irrigation up to 8 different speeds (sector irrigation). With more than 0
sectors, it is possibile to set the maximum running time of irrigation.
Press _>_ key to access a sub menu with the following SECTORS options
[NumSECT 0] This entry establishes the number of sectors that require irrigation.
Number of programmable sectors:
0 = with no supplementary features
1 = with Maximum Running Time and Initial Holding Time
2-8= with SECTORS, Maximum Running Time and Initial Holding Time
Press _>_ to access length and speed parameters of the various sectors.
(the data in this table are all modifiable and can be scrolled either up or down):
[m 1 100.0]
This entry specifies the length of sector 1. Press _>_ to display another
entry
[m/h1 25.0] This entry specifies the speed of sector 1, m/h.
[m 2 100.0] This entry specifies the length of sector 2. Press _>_ to display another
entry.
[m/h2 25.0] This entry specifies the speed of sector 2, m/h.
[m x 100.0] This entry specifies the length of sector x. Press _>_ to display another
entry
[m/hx 25.0] This entry specifies the speed of sector x, m/h.
[m 8 100.0] This entry specifies the length of sector 8. Press _>_ to display another
entry.
[m/h8 25.0] This entry specifies the speed of sector 8, m/h.
[ENMC SET]
[ENRA SET]
[ENMA SET]
[ENRU SET]
[ENMU SET]
=>Enable Modification by the Manufacturer
=>ENables Read by the Assistance
=>ENables Modification by the Assistance
=>ENables Read-only by the User.
=>ENables Modification by the User
[NoSTP mO] o
[STOP mO]
No Stop at metres = 0. Rewinding continues until the signal from the End Rewind sensor.
Or, STOP at metres = 0. Rewinding stops when the machine indicates metres of hose = 0 (ZERO).
Pressing _>_ takes you to a sub-menu with the following options:
[ENRA SmO] o
[ENMA SmO]o
[ENRU SmO]
[ENMU SmO]
=>ENables Read by the Assistance
=>ENables Modification by the Assistance
=> ENables Read-only by the User
=> ENables Modification by the User
These options enable or disable the selection of the valve position by the Assistance and the
User