Large OTR Service Crane Owner’s Manual | Page 23
Noise coming from
articulation points.
Bushings are worn. Replace bushings.
Inadequate lubrication. Lubricate bushings.
Damaged structure. Inspect and repair/replace as needed.
Broken/worn pin. Replace pin.
Stabilizers fail to
operate.
Remote/Manual switch is in
the Remote position.
Toggle switch to the Manual position.
Remote/Manual switch is
malfunctioning.
Inspect and repair/replace as needed.
Panic bar/E-Stop is engaged
(Models 9000/13500).
Release Panic bar/E-Stop.