TROUBLESHOOTING
PROBLEM CODE DEFINITION
LO Temperature is below 0°C (32°F), heating will be always active
HI Temperature is above 50°C (122°F), heating will be always inactive
--
Temperature sensor is defective, heating will always be inactive.
Call tech support.
Err
The connection could not be established with the Z-wave network.
Make sure the thermostat is within range of the Z-Wave controller
or a Z-Wave repeater and make sure the Z-Wave controller is in
Inclusion or Exclusion mode.
E1
Secondary temperature sensor is defective. The thermostat will
still control the temperature but performance may be degraded.
Consider replacing the thermostat.