OPERATION
Commissioning
ENGLISH
www.stiebeleltronamericas.com DCE Trend| 11
10.2 Temperature setting via jumper slot - operating
voltage 240 V
43°C | 109°F
50°C | 122°F
55°C | 131°F
60°C | 140°F
D0000073624
Jumper position Description
43°C | 109°F
@
240 V Forexample in nurseries, hospitals, etc.
50°C | 122°F
@
240 V Factory setting, typical DHW
55°C | 131°F
@
240 V Max. for shower operation
60°C | 140°F
@
240 V Commercial kitchen / health code
No jumper Limit 43°C | 109°F
@
240 V
f Install the jumper in the required position on the “Tmax” pin
strip.
10.2.1 Temperature rise chart at 220V operating voltage
The maximum outlet temperature of each jumper position during
normal load operation depends on the operating voltage and the
incoming water temperature.
41 50 59 68 77 86 95 104 113 122 131 140
77
86
95
104
113
122
131
140
25
30
35
40
45
50
55
60
5 10 15 20 25 30 35 40 45 50 55 60
43°C / 109°F 50°C / 122°F 55°C / 131°F 60°C / 140°F
°C
°F
D0000093035
X Inlet temperature
Y Outlet temperature
10.2.2 Temperature rise chart at 208V operating voltage
The maximum outlet temperature of each jumper position during
normal load operation depends on the operating voltage and the
incoming water temperature.
41 50 59 68 77 86 95 104 113 122 131 140
77
86
95
104
113
122
131
140
25
30
35
40
45
50
55
60
5 10 15 20 25 30 35 40 45 50 55 60
43°C / 109°F 50°C / 122°F 55°C / 131°F 60°C / 140°F
°C
°F
D0000093034
X Inlet temperature
Y Outlet temperature
CAUTION Burns
If the water supplied to the appliance is preheated, the
internal anti-scalding protection limit may be exceeded.
In such cases, limit the temperature with an upstream
central thermostatic valve.
10.3 Initial start-up
Note
During initial start-up, you MUST engage the AE3 safe-
ty switch by depressing the white reset button before
supplying power to the water heater. The unit will NOT
operate until the safety switch has been engaged.
≥ 3 min.
1
2
D0000053277
f Open and close all connected draw-off valves at least five
times total. Let water run for at least three minutes, until all
air has been purged from the pipework and the water heater.
f Ensure there are no water leaks from any plumbing
connections.
10.3.1 Initial AE3 safety switch activation
D0000073622
f Engage the AE3 safety switch by firmly pressing the white
reset button until it clicks and fully locks in place (the water
heater is delivered with the safety switch disengaged).