OPERATION
Specication
18 | DCE Trend www.stiebeleltronamericas.com
16.3 DHW output
The DHW output is subject to the connected power supply, the
water heater's selected power output, and the cold water inlet
temperature. The rated voltage and rated output can be found on
the type plate. See section 10.2, “Temperature setting via jumper
slot - operating voltage 240 V”, pg. 11 for further information.
Power output in kW 100 °F DHW output in gpm
Rated voltage Cold water inlet temperature
120V 208V 220V 240V 41 °F 50 °F 59 °F 68 °F
3.0 0.34 0.40 0.50 0.63
4.5 0.50 0.61 0.74 0.95
5.4 0.61 0.74 0.90 1.14
5.0 0.58 0.69 0.82 1.06
6.1 0.69 0.82 1.00 1.27
6.0 0.69 0.82 0.98 1.27
7.2 0.82 0.98 1.19 1.51
5.4 0.61 0.74 0.90 1.14
7.2 0.82 0.98 1.19 1.51
6.0 0.69 0.82 0.98 1.27
8.0 0.92 1.08 1.32 1.66
7.2 0.82 0.98 1.19 1.51
9.6 1.11 1.29 1.59 2.01
9.0 1.03 1.22 1.48 1.88
10.7 1.22 1.45 1.74 2.25
10.0 1.14 1.35 1.64 2.09
12.0 1.37 1.61 1.98 2.51
12.0 1.37 1.61 1.98 2.51
14.4 1.64 1.93 2.35 3.01
Power output in kW 122 °F DHW output in gpm
Rated voltage Cold water inlet temperature
120V 208V 220V 240V 41 °F 50 °F 59 °F 68 °F
3.0 0.26 0.29 0.32 0.37
4.5 0.37 0.42 0.48 0.55
5.4 0.45 0.50 0.58 0.69
5.0 0.42 0.48 0.53 0.63
6.1 0.50 0.58 0.66 0.77
6.0 0.50 0.55 0.63 0.77
7.2 0.61 0.69 0.77 0.90
5.4 0.45 0.50 0.58 0.69
7.2 0.61 0.69 0.77 0.90
6.0 0.50 0.55 0.63 0.77
8.0 0.66 0.77 0.87 1.00
7.2 0.61 0.69 0.77 0.90
9.6 0.79 0.90 1.03 1.22
9.0 0.77 0.85 0.98 1.14
10.7 0.90 1.00 1.16 1.35
10.0 0.85 0.95 1.08 1.27
12.0 1.00 1.14 1.29 1.51
12.0 1.00 1.14 1.29 1.51
14.4 1.22 1.35 1.56 1.82
Power output in kW 38°C DHW output in l/min.
Rated voltage Cold water inlet temperature
120V 208V 220V 240V 5°C 10°C 15°C 20°C
3.0 1.3 1.5 1.9 2.4
4.5 1.9 2.3 2.8 3.6
5.4 2.3 2.8 3.4 4.3
5.0 2.2 2.6 3.1 4.0
6.1 2.6 3.1 3.8 4.8
6.0 2.6 3.1 3.7 4.8
7.2 3.1 3.7 4.5 5.7
5.4 2.3 2.8 3.4 4.3
7.2 3.1 3.7 4.5 5.7
6.0 2.6 3.1 3.7 4.8
8.0 3.5 4.1 5.0 6.3
7.2 3.1 3.7 4.5 5.7
9.6 4.2 4.9 6.0 7.6
9.0 3.9 4.6 5.6 7.1
10.7 4.6 5.5 6.6 8.5
10.0 4.3 5.1 6.2 7.9
12.0 5.2 6.1 7.5 9.5
12.0 5.2 6.1 7.5 9.5
14.4 6.2 7.3 8.9 11.4
Power output in kW 50°C DHW output in l/min.
Rated voltage Cold water inlet temperature
120V 208V 220V 240V 5°C 10°C 15°C 20°C
3.0 1.0 1.1 1.2 1.4
4.5 1.4 1.6 1.8 2.1
5.4 1.7 1.9 2.2 2.6
5.0 1.6 1.8 2.0 2.4
6.1 1.9 2.2 2.5 2.9
6.0 1.9 2.1 2.4 2.9
7.2 2.3 2.6 2.9 3.4
5.4 1.7 1.9 2.2 2.6
7.2 2.3 2.6 2.9 3.4
6.0 1.9 2.1 2.4 2.9
8.0 2.5 2.9 3.3 3.8
7.2 2.3 2.6 2.9 3.4
9.6 3.0 3.4 3.9 4.6
9.0 2.9 3.2 3.7 4.3
10.7 3.4 3.8 4.4 5.1
10.0 3.2 3.6 4.1 4.8
12.0 3.8 4.3 4.9 5.7
12.0 3.8 4.3 4.9 5.7
14.4 4.6 5.1 5.9 6.9
16.4 Application areas/conversion table
Electrical resistivity and electrical conductivity.
Standard specifica-
tion at 15°C
20°C
25°C
Resis-
tivity
ρ≥
Conductivity σ≤
Resis-
tivity
ρ≥
Conductivity σ≤
Resis-
tivity
ρ≥
Conductivity σ≤
Ωcm mS/m μS/cm Ωcm mS/m μS/cm Ωcm mS/m μS/cm
1100 91 910 970 103 1031 895 112 1117
Pressure drop, sizing the pipework
When calculating the size of the pipework, an water heater pres-
sure drop of 14.5 psi (0.1MPa) is recommended.
16.5 Fault conditions
In the event of a fault, temperatures up to 176 °F (80 °C) at a pres-
sure of 145 psi (1.0 MPa) can occur briefly in the installation.