ENGLISH
61
- The tap can reach temperatures in excess of
70°C. There is a risk of scalding at outlet tem-
peratures in excess of 43°C.
- The appliance is suitable for supplying a
shower (shower operation). If the appliance
is also or exclusively used for shower opera-
tion, the qualified contractor must adjust the
temperature setting range to 55°C or less
using the internal anti-scalding protection on
the appliance. When using preheated water,
it must be ensured that the inlet temperature
does not exceed 55°C.
- Ensure the appliance can be separated from
the power supply by an isolator that discon-
nects all poles with at least 3mm contact
separation.
- The specified voltage must match the mains
voltage.
- The appliance must be connected to the earth
conductor.
- The appliance must be permanently connect-
ed to fixed wiring.
- Secure the appliance as described in chapter
"Installation/ Installation".
- Observe the maximum permissible pressure
(see chapter "Installation/ Specification/ Data
table").
- The specific water resistivity of the mains
water supply must not be undershot (see
chapter "Installation/ Specification/ Data
table").
- Drain the appliance as described in chapter
"Installation/ Maintenance/ Draining the
appliance".