92
14. Alternative installation methods
On unfinished walls, connected from above IP25
On unfinished walls, connected from below, short
power cable
IP25
On finished walls IP 24
On finished walls IP 24
Installation with offset tiles IP25
Pivoting appliance cover IP25
WARNING Electrocution
Before any work on the appliance, disconnect all poles
from the power supply.
14.1 Internal anti-scalding protection
CAUTION Burns
If operating with preheated water, the set temperature
limit and internal anti-scalding protection may be in-
effective.
In this case, limit the temperature with an upstream cen-
tral thermostatic valve.
The appliance is equipped with an anti-scalding protection func-
tion, which the qualified contractor can set if required. To do this,
the appliance must be opened.
Anti-scalding protection activation
Press the "Service" button on the PCB in the appliance.
D0000053276
1
1 "Service" button in the appliance
The "Internal anti-scalding protection" (in the "Settings/ Service"
menu) is visible for 5minutes.
Set the anti-scalding protection temperature.
Tap on "Active" and then the tick symbol to enable anti-scald-
ing protection.
20 - 60 Setting range (= temperature in °C)
43 Forexample in nurseries, hospitals, etc.
50
55 Max. for shower operation
60 Factory setting