ENGLISH
85
10. Installation
Internal anti-scalding pro-
tection in °C
60 60
Connected load in kW 21 27
Electrical connection from
below on unfinished walls
x x
Water connection on unfin-
ished walls
x x
For further installation options, see chapter "Alternative instal-
lation methods".
11. Standard installation
Opening the appliance
D0000053271
Open the appliance by holding the fascia at the side and pull-
ing forwards away from the appliance cover. Undo the screw.
Pivot open the appliance cover.
D0000053272
Remove the back panel by pressing the two locking tabs and
pulling the lower back panel section forwards.