INSTALLATION
Maintenance
14. Maintenance
WARNING Electrocution
Before any work on the appliance, disconnect all poles
from the power supply.
Draining the appliance
You can drain the appliance for maintenance work or to protect
it from frost.
WARNING Burns
Hot water may escape when draining the appliance.
f Close the 3-way ball shut-off valve or the shut-off valve in the
cold water supply line.
f Open all draw-off valves.
f Undo the water connections on the appliance.
f Store the dismantled appliance free from the risk of frost, as
water residues remaining inside the appliance can freeze and
cause damage.
Cleaning the strainer
D0000042708
A strainer is fitted in the 3-way ball shut-off valve. In case of con-
tamination, you can remove this strainer and clean it.
f Close the 3-way ball shut-off valve or the shut-off valve in the
cold water supply line.
f Remove the plastic profile washer and the strainer and clean
the components.
f Fit the strainer and the plastic profile washer.
15. Specification
15.1 Dimensions and connections
17
30
67
320
15
370
140
220
≤12
35
130
100
141
c01
c06
32
b02
D0000017978
DHF C
b02 Entry electrical cables I
c01 Cold water inlet Male thread G 1/2 A
c06 DHW outlet Male thread G 1/2 A
Alternative connection options
17
30
67
35
b02
b03
D0000025571
DHF C
b02 Entry electrical cables I
b03 Entry electrical cables II