INSTALLATION
Installation
Removing
the
flow
limiter
Notice
If
you
are
using
a
thermostatic
valve,
you
must
not
re-
move
the
flow
limiter.
If
the
flow
rate
is
too
low,
remove
the
flow
limiter.
To
do
this,
remove
the
function
module
from
the
appliance
back
panel.
>
Release
the
locking
tab.
>
Push
the
function
module
on
the
back
panel
gently
backwards.
>
Remove
the
function
module
from
the
appliance
back
panel
by
pulling
it
slightly
forwards
and
lifting
it
off.
1
Cold
water
pipe
bend
with
recess
for
spring
clip
2
0-ring
3
Flow
limiter
4
Spring
clip
5
Heater
>
Remove
the
cold
water
pipe
bend
and
the
0-ring.
>
Remove
the
flow
limiter
from
the
cold
water
inlet
of
the
heat-
er
using
a
pointed
object
or
suitable
pliers.
>
Fit
the
cold
water
pipe
bend
with
the
0-ring.
O
Property
damage
The
0-ring
must
be
fitted
to
prevent
the
appliance
from
leaking.
>
As
part
of
installation,
check
that
the
0-ring
is
in
place.
>
Secure
the
cold
water
pipe
bend
with
the
spring
clip.
O
Property
damage
Ensure
that
the
spring
clip
is
located
behind
the recess
in
the
pipe
bend
and
that
it
is
securely
holding
the
pipe
bend
in
place.
>
Fit
the
function
module
on
the
appliance
back
panel
in
re-
verse
order
until
it
clicks
into
place.
30