INSTALLATION
Installation
alternatives
-
13.2
Electrical
connection
on
unfinished
walls
from
below
with
short
power
cable
>
Reposition
the
mains
terminal
further
downwards.
To
do
this,
undo
the
fixing
screw.
Secure
the
mains
terminal
in
place.
13.3
Electrical
connection,
surface-
mounted
[il
-E1
Notice
This
type
of
connection
changes
the
IP
rating
of
the
ap-
pliance.
>
Change
the
type
plate.
Cross
out
"
IP
25"
and
mark
the
box
"
IP
24".
Use
a
ballpoint
pen
to
do
this.
i
Cable
grommet
Electrical
connection,
surface-
mounted
Positioned
in
lower
section
of
appliance
Positioned
in
upper
section
of
appliance
110
Dimension
A
160
>
Prepare
the
power
cable.
Fit
the
cable
grommet.
Property
damage
If
you
break
out
the
wrong
knock-out
in
the
back
panel/
appliance
cover
by
mistake,
you
must
use
a
new
back
panel/appliance
cover.
>
Cleanly
cut
and
break
out
the
required
cable
entries
from
the
back
panel
and
appliance
cover
(
for
the
positions,
see
chap-
ter "
Specification /
Dimensions
and
connections").
Deburr any
sharp
edges
with
a
file.
>
Route
the
power
cable
through
the
cable
grommet.
>
Connect
the
power
cable
to
the
mains
terminal.
13.4
Connecting
a
load
shedding
relay
Install
a
load
shedding
relay
in
the
distribution
board
in
conjunc-
tion
with
other
electric
appliances,
e.g.
electric
storage
heaters.
The
relay
responds
when
the
instantaneous
water
heater
starts.
O
Property
damage
Connect
the
phase
that
switches
the
load
shedding
relay
to
the
indicated
terminal
of
the
mains
terminal
in
the
appliance (
see
chapter "
Specification /
Wiring
diagram").
13.5
Water
installation,
surface-
mounted
MEI
Notice
This
type
of
connection
changes
the
IP
rating
of
the
ap-
pliance.
>
Change
the
type
plate.
Cross
out
"
IP
25"
and
mark
the
box
"
IP
24".
Use
a
ballpoint
pen
to
do
this.
I>
Fit
water
plugs
with
gaskets
to
seal
the
concealed
connec-
tions.
All
taps
obtained
as
accessories
are
supplied
with
plugs
and
gaskets
in
the
standard
delivery.
For
pressure
taps
other
than
those
recommended
by
us,
plugs
and
gaskets
can
be
ordered
as
accessories.
>
Fit
a
suitable
pressure
tap.
>
Push
the
lower
back
panel
section
under
the
connection
pipes
of
the
tap
and
push
it
into
the
back
panel.
>
Secure
the
connection
pipes
to
the
tee
and
the
3-
way
ball
shut-off
valve.
M
Notice
You
can
break
off
the
pipe
fitting
tabs
on
the
lower
back
panel
section
if
required.
1
Tab
34
I
HDB-E
Trend
www.stiebel-eltron.com