40
10.9 Data table
The output data refers to new appliances with clean heat ex-
changers. The power consumption of the integral auxiliary drives
represents the maximum value and may vary subject to operating
point. The power consumption of the integral auxiliary drives is
included in the output details of the appliance (to EN14511).
201427 201290
Heating output
Heating output at A-7/W35 (EN 14511) kW 5.50 8.34
Heating output at A2/W35 (EN 14511) kW 5.16 5.16
Heating output at A7/W35 (EN14511) kW 4.40 4.40
Heating output, emergency/booster heater kW 2.9 / 5.8 / 8.8 2.9 / 5.8 / 8.8
Cooling capacity at A35/W7 kW 2.40 2.69
Max. heating output kW 14.3 17.2
Power consumption
Power consumption at A-7/W35 (EN 14511) kW 3.19 3.19
Power consumption at A2/W35 (EN 14511) kW 1.38 1.38
Power consumption at A7/W35 (EN14511) kW 0.93 0.93
Coefficient of performance
COP at A-7/W35 (EN 14511) 2.61 2.61
COP at A2/W35 (EN 14511) 3.74 3.74
COP at A7/W35 (EN14511) 4.74 4.74
Sound emissions
Sound power level (EN 12102) dB(A) 50 50
Sound power level, full load (EN 12102) dB(A) 59 59
Application limits
Min. application limit, heat source °C -20 -20
Max. application limit, heat source °C 35 35
Max. pressure drop, outdoor air Pa 25 25
Min. installation room volume m³ 7 7
DHW temperature with heat pump at A2 °C 50 50
Hydraulic data
Cylinder capacity l 235 235
Energy data
Energy efficiency class, heat pump W55 A++ A++
Energy efficiency class for DHW heating with load profile XL A A
Energy efficiency class for DHW heating (load profile), moderate climate A (XL) A (XL)
Energy efficiency class A++/A++ A++/A++
Electrical data
Max. power consumption, fan W 170 170
Nominal power consumption, fan W 100 100
Power consumption, fan W 100 100
Power consumption, circulation pump W < 45 < 45
Max. power consumption without emergency/booster heater kW 5.3 5.3
Fuse protection, emergency/booster heater A 3 x B 16 3 x B 16
Max. fuse protection, compressor A 1 x B 25 1 x B 25
Compressor fuse protection A 1 x B 16 1 x B 25
Fuse protection, heat pump fan A 1 x B 16 1 x B 16
Control unit fuse protection A B 16 B 16
Rated voltage, emergency/booster heater V 400 400
Rated voltage, compressor V 230 230
Rated voltage, heat pump fan V 230 230
Rated voltage, control unit V 230 230
Compressor phases 1/N/PE 1/N/PE
Heat pump fan phases 1/N/PE 1/N/PE
Control unit phases 1/N/PE 1/N/PE
Frequency Hz 50 50
Total power consumption A 20 20
Starting current (with/without starting current limiter) A -/8 -/8
Emergency/booster heater phases 3/N/PE 3/N/PE