INSTALLATION
Installation
20 | SHP-F 220-300 Premium www.stiebel-eltron.com
Air duct connection
Note
Connect the appliance and the air duct system using a
flexible method, e.g. a flexible ventilation pipe, to reduce
noise and vibrations.
Connect a flexible 500 cm hose to the air duct.
Note
The installation of a thermally insulated air hose is de-
scribed as an example.
D0000047030
3
2
1
1 Air connector
2 Internal hose
3 External hose
Pull the internal hose of the air hose slightly out of the exter-
nal hose and thermal insulation.
D0000047031
Invert the internal hose halfway down the connector.
D0000047032
Seal the transition from the internal hose to the connector
with self-adhesive thermal insulation tape.
D0000047033
Pull the external hose and the thermal insulation below it
over the connector.
Tuck the thermal insulation into the outer hose in such a way
that the thermal insulation is no longer visible.
D0000047034
Seal the transition from the external hose to the connector
with self-adhesive thermal insulation tape.
D0000047035
Secure the external hose with the hose clip to the connector.
D0000047036
The air hose tends to sag because of its flexibility. Secure it
at intervals of approx. 1m.
Insulate the air duct and all connections in line with insula-
tion standards if used for waste heat or outside air to prevent
condensation on these components.