16.4 Data table
SHP-F 220 Premium SHP-F 300 Premium SHP-F 300 X
Premium
238630 238631 238632
Hydraulic data
Nominal capacity l 220 302 291
Surface area, indirect coil m² 1.3
Application limits
Max. DHW temperature with heat pump °C 65 65 65
Max. DHW temperature with emergency/booster heater °C 65 65 65
Max. permissible DHW temperature inside the cylinder °C 70 70 70
High limit safety cut-out °C 92 92 92
Min./max. application limits of heat source for heat pump operation °C -8/+42 -8/+42 -8/+42
Min./max. application limits for cylinder ambient temperature °C +6/+42 +6/+42 +6/+42
Min. installation room volume (recirculation air mode, general domestic use) m³ 23 13 13
Max. permissible operating pressure, cold water/DHW MPa 0.8 0.8 0.8
Min./max. conductivity, potable water μS/cm 100-1500 100-1500 100-1500
Output data to EN 16147
Nominal DHW temperature (EN 16147) °C 55 55 55
Nominal load profile (EN 16147) L XL XL
Reference DHW temperature (EN 16147 / A20) °C 53.1 54.2 54.2
Reference DHW temperature (EN 16147/A14) °C 53.2 54.3 54.3
Reference DHW temperature (EN 16147 / A7) °C 52.8 54.3 54.3
Reference DHW temperature (EN 16147/A2) °C 54.4 54.8 54.8
Maximum available nominal amount of DHW at 40°C (EN 16147 / A20) l 284 422 399
Maximum available nominal amount of DHW at 40°C (EN 16147 / A14) l 283 423 399
Maximum available nominal amount of DHW at 40°C (EN 16147 / A7) l 267 422 394
Maximum available nominal amount of DHW at 40°C (EN 16147 / A2) l 268 408 380
Rated heating output Prated (EN 16147/A20) kW 1.51 1.67 1.67
Rated heating output Prated (EN 16147 / A14) kW 1.48 1.54 1.46
Rated heating output Prated (EN 16147 / A7) kW 1.08 1.3 1.12
Rated heating output Prated (EN 16147 / A2) kW 0.9 0.95 0.88
Heat-up time (EN 16147 / A20) h 6.57 9.27 9.27
Heat-up time (EN 16147 / A14) h 6.68 9.56 9.56
Heat-up time (EN 16147 / A7) h 8.65 11.32 12.24
Heat-up time (EN 16147 / A2) h 10.34 15.04 15.04
Power consumption, standby period (EN 16147 / A20) kW 0.025 0.023 0.027
Power consumption, standby period (EN 16147 / A14) kW 0.025 0.025 0.029
Power consumption, standby period (EN 16147 / A7) kW 0.021 0.027 0.027
Power consumption, standby period (EN 16147 / A2) kW 0.030 0.030 0.034
COP (EN 16147 / A20) 3.28 3.75 3.75
COP (EN 16147 / A14) 3.27 3.60 3.60
COP (EN 16147 / A7) 3.07 3.22 2.99
COP (EN 16147 / A2) 2.71 2.60 2.60
Heating output
Average heating output (A20 / W10-55) kW 1.8 1.8 1.8
Average heating output (A14 / W10-55) kW 1.7 1.7 1.7
Average heating output (A7 / W10-55) kW 1.3 1.3 1.3
Average heating output (A2/W10-55) kW 1.1 1.1 1.1
Power consumption
Average power consumption of heat pump (A20/W10-55) kW 0.4 0.4 0.4
Average power consumption of heat pump (A14/W10-55) kW 0.4 0.4 0.4
Average power consumption of heat pump (A7/W10-55) kW 0.4 0.4 0.4
Max. heat pump power consumption (excl. start-up) kW 0.65 0.65 0.65
Max. power consumption, heat pump + emergency/booster heater kW 2.15 2.15 2.15
Energy data
DHW heating energy efficiency class (load profile), indoor air A+ (L) A+ (XL) A+ (XL)
Energy efficiency class for DHW heating (load profile), outdoor air A+ (L) A+ (XL) A+ (XL)
Electrical data
Power supply 1/N/PE ~ 230V 50 Hz 1/N/PE ~ 230V 50 Hz 1/N/PE ~ 230V 50 Hz
Permissible voltage range, external signal transmitter ~ 230V 50Hz ~ 230V 50Hz ~ 230V 50Hz
Max. operating current A 8.54 8.54 8.54
Max. starting current A 23.44 23.44 23.44
Fuse protection A C16 C16 C16