51
Adjustment channel Description Adjustment range / selection Factory setting
Relay Relay selection system dependent system dependent
Sensor top Top sensor selection system dependent system dependent
Sensor base Base sensor selection system dependent system dependent
TBoiler on Boiler switch-on temperature 0 ... 94 °C [32 ... 202 °F] 45 °C [114 °F]
TBoiler o Boiler switch-o temperature 1 ... 95 °C [34 ... 204 °F] 60 °C [140 °F]
Timer Timer option Yes, No No
Timer Timer - -
Days of the week Day selection
All days, Monday ... Sunday,
Continue
-
Timer Time frame adjustment 00:00 ... 23:45 -
Funct. Activation / Deactivation Activ., Deactivated Deactivated
Arrangement / Opt. functions / Add new function... / Boiler loading
Error relay The error relay function can be used to operate a
relay in the case of an error. Thus, e. g. a signalling
device can be connected to signal errors.
If the error relay function is activated, the allocated
relay will be energised when a sensor fault occurs.
If the ow rate monitoring function is activated, the
error relay will additionally energised in the case of
a ow rate error.
Adjustment channel Description Adjustment range / selection Factory setting
Relay Relay selection system dependent system dependent
Funct. Activation / Deactivation Activ., Deactivated Deactivated
Arrangement / Opt. functions / Add new function... / Error relay