Heat exchange The heat exchange function can be used for transfer-
ring heat from a heat source to a heat sink.
The allocated relay is energised when all switch-on
conditions are fullled:
the temperature dierence between the allocated
sensors has exceeded the switch-on temperature
dierence
the temperature at the heat source sensor has
exceeded the minimum temperature
the temperature at the heat sink sensor has fallen
below the maximum temperature
If Tset is exceeded, pump speed control will come
into eect. For every deviation of 2 K [4 °Ra], the
pump speed will be adjusted by 10 %.
Sensor Source
Relay
Sensor Sink
Adjustment channel Description Adjustment range / selection Factory setting
Relay Relay selection system dependent system dependent
Sen. So. Heat source sensor selection system dependent system dependent
Sen. Sink Heat sink sensor selection system dependent system dependent
Ton Switch-on temperature dierence 1.0 ... 30.0 K [2.0 ... 60.0 °Ra] 6.0 K [12.0°Ra]
To Switch-o temperature dierence 0.5 ... 29.5 K [1.0 ... 59.0 °Ra] 4.0 K [8.0°Ra]
Tset Set temperature dierence 1.5 ... 40.0 K [3.0 ... 80.0 °Ra] 10.0 K [20.0°Ra]
Min. speed Minimum speed 30 ... 100 % 30 %
Tmax
Maximum temperature of the
store to be loaded
10 ... 95 °C [50 ... 204 °F] 60 °C [140 °F]
Tmin
Minimum temperature of the
store to be loaded
10 ... 95 °C [50 ... 204 °F] 10 °C [50 °F]
Funct. Activation / Deactivation Activ., Deactivated Deactivated