2 Adjustments
2.1 Operating modes
(Control level 1)
The operating modes are changed by pressing
with the control flap closed.
Standby mode
Frost protection is activated for central hea-
ting and DHW operation. The display indicates
frost protection when the flap is closed.
The set DHW temperature is permanently
set to 10 °C; the set central heating flow tem-
perature is calculated in relation to a set room
temperature of 5 °C, see point 3.
Application: During holidays.
Automatic mode
Heating subject to time switch program (ap-
plies to HC1 and HC2), changeover between
day temperature and setback temperature.
DHW in accordance with a time switch pro-
gram, changeover between day temperature
and setback temperature, see point 4. With
this operating mode, an additional symbol (sun
or moon) indicate, whether heating circuit 1 is
currently in day or in setback mode.
The remote control is only active in this
mode.
Application: If you need heating and DHW.
Constant day mode
The heating circuit is constantly held at the
day temperature (applicable to HC1 and
HC2).
DHW according to time switch program.
Application: In low energy houses without set-
back operation.
Constant setback mode
The heating circuit is constantly held at the
setback temperature (applicable to HC1 and
HC2).
DHW according to time switch program.
Application: During weekends.
DHW operation
DHW in accordance with a time switch pro-
gram, changeover between day temperature
and setback temperature. Frost protection is
activate for central heating operation.
Application: When the heating period ends;
only DHW should be generated (summer
mode).
Heat source (HS 2)
This setting activates the emergency mode.
With the HP type 2, the HS 2 provides cen-
tral heating and DHW loading during this
operating mode, independent of the dual
mode changeover point of heating and DHW
loading.
For HP types 1 and 3, HS 2 for heating and
DHW must be set to ON at control level 3;
only then can the operating mode be selected.
With this operating mode, HS 2 takes over
the heating or DHW function, independent of
the dual mode changeover point.
Error message (ashing)
ndicates faults in the heat pump ystem.
Inform your local contractor
Display (including all elemets)
14-digit plain text display
Compress run
Heating times for central heating and DHW (black)
2. HS RUN
Switching time pairs for central heating and DHW operation
DEFROST
Day mode HC 1
Setback mode for heating circuit 1
Heat source 2 (emergency work)
DHW operation
Constant setback mode
Constant day mode
Automatic mode
Standby mode
Fault message (flashing)
C26_03_01_0206