Heating programs
The HTG PROG menu item enables you to
adjust associated heating programs for hea-
ting circuit 1 and 2 respectively.
You can adjust your heating system as follows:
– for each individual day of the week
(Monday, ..., Sunday)
– Monday to Friday (Mo - Fr)
– Saturday and Sunday (Sa - Su)
– the whole week (Mo - Su)
You can adjust three switching time pairs
(I, II, III) for each of these options.
This determines, when and how often the
heat pump system should heat in day mode.
At all other times, the heat pump operates in
setback mode. You will already have selected
the corresponding set values for day and set-
back mode under menu item
ROOM TEMP 1/2.
Example: For heating circuit 1, your heating
system should operate daily from Monday to
Friday at two different times, i.e. from 05:30
h until 08:30 h as well as from 14:00 h until
22:00 h. For the weekend, your heating sys-
tem should provide heat from 08:30 h until
21:00 h.
Open the control ap.
Heating circuits
1 or 2
Heating PROG
Heat Circuit 1
Mon to FRI
HEAT START 21C
Heat STOP 21C
Heat START 21C
Heat STOP 21C
Heat START 21C
SAT to SUN
Heat START 21C
Heat STOP 21C
Heat START 21C
Heat START 21C
SAT to SUN
BACK
BACK
HEATING PROG