STIHL 029, 039 51
Top:
Removing annular buffer
Bottom:
Removing handle housing and
pushing out manifold at same time
Top:
Removing grommet
Bottom:
Removing the impulse
hose
Top:
Ground wire
Bottom:
Plug
- Pull the ground wire off the
contact spring.
- Ease the plug out of the annular
buffer on the hand guard.
- Push the annular buffer out of the
engine housing.
- Pull the handle housing slightly
forward and push the manifold
through the handle housing
opening at the same time.
- Ease the grommet for the ground
and short circuit wires out of the
handle housing.
- Remove the impulse hose from
the handle housing.
- Remove the handle housing and
pull the ground and short circuit
wires out of the bore at the same
time.
Assembly is a reversal of the
disassembly sequence.