EasyManua.ls Logo

Stihl BR 500 - 11 Fan; Outer Fan Housing

Stihl BR 500
62 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
55BR 500, BR 550, BR 600
: Push the locking tabs (arrows)
down and lift the protective
screen (1) upwards and away.
Install in the reverse sequence.
452RA086
1
VA
: Locate lugs (1) on bottom of
protective screen in the holes
(arrows) in the base of the
backplate.
Carefully push the upper half of
the protective screen against the
backplate until the locking tabs
452RA087
VA
11
snap into position.
Install all other parts in the reverse
sequence.
: Unclip the throttle cable (1) with
grommet (3) from the hose
clamp (2).
: Take out the screw (arrow).
: Remove the hose clamp (2) and
pleated hose.
452RA154
2
VA
3
1
: Disconnect the lower half of the
antistatic wire (1) from the upper
half (2).
Take the powerhead off the
backplate, b 10.2
452RA155
1
VA
2
: Take out the screws (arrows).
: Remove the outer fan
housing (1).
: Remove the elbow (2).
Install in the reverse sequence.
452RA088
1
VA
2
11. Fan
11.1 Outer Fan Housing
RA_452_00_01_02.book Seite 55 Donnerstag, 16. Februar 2012 11:52 11