57BR 500, BR 550, BR 600
Install in the reverse sequence.
Do not lubricate the thread of the
fanwheel.
– Remove the fanwheel, b 11.3
: Take out the screw (1).
: Remove the antistatic wire (2).
Install in the reverse sequence.
Check installed position of antistatic
wire.
: When installing, make sure the
crimping (arrow) on the cable lug
faces outwards.
Install all other parts in the reverse
sequence.
The machine may be operated only
with a properly installed antistatic
wire.
: Check that the hook on the
antistatic wire is always
connected to the eye (arrow).
: Make sure the sleeve on the
antistatic wire is always clipped
into the retainer (arrow).
Install all other parts in the reverse
sequence.
11.4 Antistatic Wire
RA_452_00_01_02.book Seite 57 Donnerstag, 16. Februar 2012 11:52 11