57BR 500, BR 550, BR 600
Install in the reverse sequence.
Do not lubricate the thread of the
fanwheel.
Remove the fanwheel, b 11.3
: Take out the screw (1).
: Remove the antistatic wire (2).
Install in the reverse sequence.
452RA091
2
VA
1
Check installed position of antistatic
wire.
: When installing, make sure the
crimping (arrow) on the cable lug
faces outwards.
Install all other parts in the reverse
sequence.
452RA092
VA
The machine may be operated only
with a properly installed antistatic
wire.
: Check that the hook on the
antistatic wire is always
connected to the eye (arrow).
452RA164
VA
: Make sure the sleeve on the
antistatic wire is always clipped
into the retainer (arrow).
Install all other parts in the reverse
sequence.
452RA165
VA
11.4 Antistatic Wire
RA_452_00_01_02.book Seite 57 Donnerstag, 16. Februar 2012 11:52 11