If spa mode is enabled in the service menu. If a
pool only setup, the unit will skip to vacuum cut-
off. Press the YES button, and screen will read:
Press the YES button again to start the pump, after
verifying that the valves are set to spa. Calibrating
the spa parameter set is identical to setting the pool
parameters. After the screen displays:
and the SR500 saves the spa parameters, it will display them as it did in pool mode.
The only way to edit these values is to re-run the “prime pool” or “prime spa“ func-
tion. After the spa parameters are displayed, press
SET again to continue. Screen will read: If you
see this error:
refer to the section “Troubleshooting calibration
issues”
This is the upper vacuum threshold, or how much of a vacuum spike will register as
an alarm. The factory default setting is 3” above the running reference, this should
not be changed without factory consultation.
Press the SET button to continue. Screen will
read:
enable the heater delay circuit here by pressing
the YES button. Press the SET button to continue.
Screen will read:
This is how the SR500 will return to service after a power outage. This setting
should correspond with the mode you will regularly use. Setting the Default run
mode to either Timed or Cont. will disable Remote mode. Setting the Default run
mode to Remote mode disables both Timed and
Cont. modes. After setting the Default run mode
to the proper setting, press the SET button again,
screen will read:
Press the OFF button to exit Service Mode.
VALVES SET FOR SPA?
Y/N YES = START PUMP
PLEASE WAIT...
XX.XX”Hg
DELTA-P TOO LOW!
SET TO TRY AGAIN
HEATER DELAY?
Y/N NO
VACUUM CUTOFF AT
03” ABOVE REF Y/N?
DEFAULT RUN
MODE: NONE
FIRMWARE VERSION
2.00 XX/XX/XX
31