Installation
Unpacking the appliance
This product has been packaged to protect it against transportation damage.
Unpack the appliance and remove all packaging materials from around the
oven and from inside the oven cavity.
Keep all packaging materials until you have made sure your new oven is
undamaged and in good working order. The carton is recyclable. Whenever
possible, reuse and recycle it when disposing of the packaging materials.
Plastic wrapping can be a suffocation hazard for babies and young children, so
ensure all packaging materials are out of their reach and disposed of safely.
WARNING!
This oven must be correctly installed by an appropriately qualified
electrician in accordance with all applicable rules and regulations and
following the instructions in this manual.
Do not try to install the oven yourself; doing so will expose you to danger and
void the warranty. Improper installation, adjustment, alteration or service can
cause injury or damage. We decline any responsibility for injury or damage,
to persons or property, as a result of improper use or installation.
Electrical connection: important advice for the installer
This appliance should be wired into a 16A double pole switched fused spur
outlet, having 3mm contact separation and placed in an easily accessible
position adjacent to the appliance. The spur outlet must still be accessible
even when the oven is located in its housing to enable the appliance to be
disconnected from the mains supply.
To connect the oven power cord, loosen and remove the cover on the
terminal block in order to gain access to the contacts inside. Make the
connection, securing the cord in place with the cable clamp provided and
then immediately close the terminal block cover again.
If you have to change the oven power cord, the earthing (yellow/green)
conductor must always be 10 mm longer than the line conductors.
Care must be taken to ensure that the temperature of the mains supply
cable does not exceed 50°C.
If the mains supply cable is damaged, then it must be replaced by an
appropriate replacement.