EasyManua.ls Logo

Stober FDS 4000 User Manual

Stober FDS 4000
74 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
FREQUENCY INVERTER
POSIDRIVE
®
FDS 4000
Installation and Commissioning Instructions
It is essential to read and comply with these
instructions prior to installation and
commissioning.
SV. 4.5
07/2003
FDS
POSITIONING CONTROL
VECTOR CONTROL
SYNCHRONOUS
OPERATION
TECHNOLOGY
MANA
G
EMENT
S
Y
S
TE
M
certified by DQS according to
DIN EN ISO 9001, DIN EN ISO 14001
Reg-No. 000780 UM/Q
M

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Stober FDS 4000 and is the answer not in the manual?

Stober FDS 4000 Specifications

General IconGeneral
BrandStober
ModelFDS 4000
CategoryDC Drives
LanguageEnglish

Summary

FREQUENCY INVERTER POSIDRIVE® FDS 4000

Installation and Commissioning Instructions

Provides essential guidance for installing and setting up the frequency inverter.

1. Notes on Safety

High Voltage Safety Warning

Warns about the dangers of high touch voltage and electric shock.

4. Electrical Installation

5. Connection Assignment - Control Portion

7. Operator Control and Programming

Parameterization

Details the procedure for navigating and changing inverter parameters.

8. Commissioning

Primary parameters

Lists essential parameters that must be specified before initial operation.

Motor type

Explains how to select and configure the motor parameters for optimal performance.

Analog / frequency reference value

Details how to use analog inputs or frequency signals for speed control.

Fixed reference values (digital ref. val.)

Explains how to define and select fixed speed references using digital inputs.

9. Special functions

Binary inputs BE1 to BE5 (BE6 to BE10)

Details the default meanings and programming of binary inputs for specific functions.

Torque limits

Explains how to set and manage torque limits for motor protection and control.

Parameter record selection

Explains how to manage and switch between different parameter sets.

Speed feedback

Covers the setup and commissioning of speed feedback using an incremental encoder.

Acknowledgment of faults

Explains the methods for acknowledging and resetting inverter faults and events.

10. Positioning Control

Destination positioning / process blocks

Explains how to define target positions and sequence movements using process blocks.

Absolute / relative positioning

Details the methods for specifying absolute or relative target positions for movement.

Commissioning

Outlines the steps for activating and commissioning the positioning control function.

Reference point traversing

Explains the process of establishing a known reference position for the drive.

12. Synchronous Running, El. Gearbox

Function overview

Provides an overview of the synchronous running and electronic gearbox features.

Emergency off

Provides measures to minimize divergence between master and slave during power off.

13. Parameter Description

B.. Motor

Covers parameters specific to motor configuration, selection, and characteristics.

F.. Control Interface

Details parameters for configuring inputs, outputs, and communication interfaces.

I.. Posi. Machine

Explains parameters related to the positioning machine functions and process blocks.

J.. Posi. Command (Process Blocks)

Details parameters for defining and controlling process blocks for sequential movements.

16. Operating States

17. Faults / Events

Related product manuals