2. Technical Specifications
2
FDS 4300/B*
22 kW
3 x 44 A
3 x 63 AT
550 W
13.2
15.4
FDS 4270/B*
18.5 kW
3 x 39 A
3 x 50 AT
0 to +40 °C f. nom. data,
500 W
13
15.2
FDS 4220/B*
15 kW
3 x 32 A
3 x 50 AT
420 W
12.8
15
FDS 4150/B*
11 KW
3 x 22 A
3 x 35 AT
290 W
12.4
14.6
Model 3 / BG III
FDS 4110/B*
7.5 kW
3 x 16 A
3 x 25 AT
≥ 30 Ω;
max. 21 kW const.,
220 W
186 x 410 x 268
max. 10
12.3
14.5
FDS 4085/B*
5.5 kW
3 x 12 A
3 x 20 AT
180 W
FDS 4070/B*
4.0 kW
3 x 10 A
3 x 16 AT
150 W
FDS 4040/B*
2.2 kW
3 x 5.5 A
(L1-L3) 3 x 400 V
+28%/-55%
4)
/ 50/60 Hz
3 x 10 AT
88 W
Model 2 / BG II
FBS 4028/B*
1.5 kW
3 x 7.0 A
see
FBS / BGI
1 x 16 AT
≥ 100 Ω;
max. 1,28 kW const.,
max. 6,4 kW für 0,5 s
100 W
98 x 300 x 268
max. 4.0
5
6.4
FDS 4024/B*
1.5 kW
3 x 3.5 A
77 W
FDS 4014/B
0.75 kW
3 x 2.1 A
(L1-L3) 3 x 400 V
+28%/-55%
4)
/ 50/60 Hz
3 x 6 AT
≥ 200 Ω;
max. 640 W const.,
max. 3,2 kW für 1 s
50 W
FBS 4013/B
0.75 kW
3 x 3.5 A
1 x 10 AT
53 W
Model 1 / BG I
FBS 4008/B
0.37 kW
3 x 2.1 A
(L1-N) 1 x 230 V
+20%/-55%
4)
/ 50/60 Hz
1 x 6 AT
3 x 0 V up to connection
voltage
0 - 200 Hz (vector control: 0 - 100 Hz; spindles: 0 - 400 Hz at B20=0V/f-control and B24=8 kHz) / resolution of 0.01 Hz
200 % / 2 sec , 150 % / 30 sec
4 kHz (adjustable up to 16 kHz with current derating of 46% at 16 kHz, 75% at 8 kHz)
≥ 100 Ω;
max. 320 W const.,
max. 1,8 kW für 1 s
Integrated network filter for compliance with RFI suppression in acc. w. EN 55011, classes A + B/residential and industrial zoning
EN 61000 -4 -2, -3, -4, -5/residential and industrial zoning
50 m, proportionately shorter when several motors are used. Longer lengths or parallel installation to encoder cable with output derating.
0° to 45° C for nominal data
Up to 55° C with power reduction of 2.5% /° C
-20 °C to +70 °C, Max. change, 20 K/h
Relative humidity of 85%, no condensation
36 W
IP 20
98 x 300 x 176
max. 2.5
3.2
4.3
Model
Type of device
Recommended
motor power
1)
Nominal
current I
N
2)
Connection
voltage
Power fuses
5)
Output voltage
Output frequency
I
max
Clock pulse
frequency
Braking resistance,
limit data, brake
chopper)
RFI suppression
3)
Interference
immunity
Permissible
length of motor
cable, shielded
Ambient
temperature
Storage
temperature
Humidity during
operation
Power loss
Protection rating
Dimensions
W x H x D (in mm)
Core cross section
(in mm
2
) Motor
cable/power cable
Weight (in kg)
- without packing
- with packing
* = Externally ventilated (integrated fan)
3)
Clock pulse frequency 4 kHz, motor cable shielded and applied on both sides
1)
For nominal connection voltage, clock pulse frequency 4 kHz,
4)
Power networks ≠ 400 V: Low voltage limit (A35) and A36 may have to be adjusted
.
4-pin asynchronous machine, motor cable shielded 50 m
5
Line circuit breaker - tripping characteristic D in accordance with EN 60898
2)
With S1, clock pulse frequency 4 kHz For UL conformity, use class RK1 fuses: 1~: Bussmann KTN-R (200 to 240 V)
3~: Bussmann KTS-R (380 to 500 V)