6 | Technical data STOBER
72
02/2019 | ID 442728.05
Derating – Effect of the clock frequency
0
0,5
1
1,5
2
2,5
3
3,5
4
4,5
0 100 200 300 400 500 600 700
1
2
I [A]
N
f [Hz]
Fig.12: Derating the nominal current depending on the clock frequency, TEP3720-0ES41
1 4kHz clock frequency
2 8kHz clock frequency
0
2
4
6
8
10
12
14
16
18
20
0 100 200 300 400 500 600 700
1
2
I [A]
N
f [Hz]
Fig.13: Derating the nominal current depending on the clock frequency, TEP3820-0CS41
1 4kHz clock frequency
2 8kHz clock frequency