7 QZ 70 en26 | Quartz
StoneL publication 105406revA
Wiring diagram
2 DPDT switches (QG14_, QX14_)
Applicable models
QG14_, QX14_
Specications
Electrical ratings 4.5 amp @ 125/250 VAC, 24 to 125 VDC
Temperature range -40° to 80° C
Operating life 250,000 (VAC), 100,000 (VDC) cycles
Warranty Two years
Not recommended for electrical circuits operating at less than 20 mA @ 24 VDC
4.4 Mechanical micro switches
4.4.2 DPDT switches (14)
TOP C1
TOP C2
TOP NC1
TOP NO1
TOP NO2
TOP NC2
BTM NC1
BTM NO1
BTM C1
BTM C2
BTM NO2
BTM NC2
C1 C2 NO2 NC2
BTM
NO1NC1NC2NO2
TOP
NC1 NO1 C1 C2
top switch
(individual elements actuate
with common plunger)
bottom switch
(individual elements actuate
with common plunger)
Additional 3-pole
terminal block
provided in unit
for solenoid
termination
Caution: To prevent ignition of hazardous atmospheres,
replace cover before energizing the electrical circuits. Keep
cover tightly closed within operation.
Touch & Tune switch setting
1. Lift bottom cam and rotate until sensor is activated. Release cam
and be sure it slides fully onto spline.
2. Operate actuator to opposite position, push down on top cam and
repeat process.