Remedying Faults in PP 1207Klöckner ller
Remedying faults PP 1207
page 26 April 2005
Operating voltage
Output terminals
Bridged
Terminals for the sensor
Fault lights for Terminals 6 and 7: Each sensor has two switches. If both switches do
not reach the same switching status within three seconds, the device disables the
machine and both LEDs light up. If only one LED lights up, change the evaluation unit
and then check again.
Fault indicating LEDs
2.3 Machine does not start
E. Evaluation unit of the safety switch faulty