2. if starting boot message is displayed, Do Download again
by suitable Firmware to model.
3. Do STB Power off/on after Download is completed.
4. If screen is displayed, it does FACTORY RESET necessarily.
2) When Message is displayed:
(Message can be different according to Firmware Version)
Set ACLK <32000>
PHILIPS TDA8044 connected
IT520S SET-TOP BOX MONITOR v1.10 BY INTEGRA TELECOM
Nov 02 2000,23:35:35, http: www.integra.co.kr
>size of sysconfig=140
flash pattern(ffff)
flash pattern(ffff)
flash pattern(ffff)
PHILIPS TDA8044 connected
Enable AV Interrupts
launch OSD
launch OSD 3
Set ACLK <3>
launch OSD 4
launch OSD 4.5
launch OSD 5
intr EN end[D:0][AV:3c00]
RegValue23=3
AVO:OSD Initialized
AV decoder and OSD initialized
1. When I2C ERROR ,EEPROM ERROR,TUNER CONNECT
FAIL message happens After AC POWER OFF, measuring
resistance between U1's pin 156 and GND, pin 155 and GND, if
it is measured (20ohm ~ 0 ohm), L64108 ( CPU ) must change.
2. When EEPROM ERROR Message happens