EasyManua.ls Logo

Strymon Riverside - Power Up Modes; Power Up Mode Configurations

Strymon Riverside
43 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Riverside - Multistage Drive
®
pg 38
Power Up Modes
BYPASS MODE
(See page 13 for an
illustrated description)
SET MIDI CHANNEL
(See page 28 for an
illustrated description)
FACTORY RESET
(See page 23 for an
illustrated description)
GENERAL SETTINGS
Turn LEVEL knob - status shown on ON LED
True Bypass = Green (default)
Buffered Bypass = Red
Turn DRIVE knob - status shown on
FAVORITE LED
1 = Green (default)
2 = Amber
3 = Red
4-16 = Blue (channel set by next MIDI
Program Change message)
Sweep MIDDLE knob twice to RESET -
status shown on FAVORITE LED
Turn 1 = Amber
Turn 2 = Red
Turn 3 = Amber
Turn 4 = Both LEDs flash Red, pedal
resets & power cycles
Press and Hold the ON footswitch at power
up until the LEDs flash. Release and use
knobs as described below. Press any
footswitch to store settings & exit.
Below is a list of global parameters and functions that are
accessed via a power up procedure. All power up functions persist
through power cycles.